Kompetenz in der dentalen Chirurgie und Implantologie
Go to wishlist Wishlist

Shopping cart

Your cart is currently empty

Product image slideshow Items

  • MCTBio Bone Profiler Kit – Remove Bone at the Implant Shoulder

MCTBio Bone Profiler Kit – Remove Bone at the Implant Shoulder

€398,00 €325,00 *
* Excl. tax Excl. Shipping costs

MCTBio bone profiler kit by Mr. Curette Tech, Korea: removes overgrown bone at the implant shoulder during uncovering – centred via guide pin so healing abutments and impression copings seat fully.

UNCOVERING · MCT BIO (MR. CURETTE TECH, KOREA)
MCTBio Implant Bone Profiler Kit
When uncovering submerged implants, the implant shoulder is often overgrown with bone – healing abutments, impression copings or abutments then don't seat fully. The bone profiler removes this bone precisely and centred around the implant shoulder without touching the implant.
USE
uncovering
submerged healing
PRINCIPLE
guide pin
screwed into the implant
PROTECTION
implant shoulder
remains untouched
SYSTEMS
universal
common internal threads
MANUFACTURER
MCT Bio
Korea
BONE AT THE SHOULDER
So prosthetic parts seat fully

When bone grows over the implant shoulder, healing abutments and impression copings do not sit flush. The result is gaps, inaccurate impressions and misfits of the final crown.

With the bone profiler, a guide pin is screwed into the implant. The profiling cutter slides over it and removes only the excess bone in a circular motion – exactly centred and down to the implant shoulder.

MCTBio implant bone profiler kit
Bone profiler kit
WORKFLOW
Clearing the implant shoulder

1. Uncover the implant, remove the cover screw.
2. Screw the matching guide pin into the implant's internal thread.
3. Choose the profiling cutter matching the diameter of the planned healing abutment or abutment.
4. Place the cutter over the guide pin and remove the excess bone at low speed with irrigation.
5. Remove the guide pin, check the implant shoulder, insert the healing abutment.

PRACTICAL TIPS
What matters
 
  • Do not choose a cutter larger than necessary – this preserves the buccal bone wall.
  • Always work with a guide pin so the cutter runs centred and does not damage the shoulder.
  • Check the seat of the healing abutment or impression coping radiographically if needed.
  • Clean and sterilise instruments after each use; replace blunt cutters.
Note: For use by trained dental professionals only. Speed, irrigation and reprocessing according to the manufacturer's instructions for use.
Please accept cookies to help us improve this website Is this OK? Yes No More on cookies »