INNO Sonator Abutment

€118,00 *

* Excl. tax Excl. Shipping costs

INNO Sonator abutment for overdentures on Cowellmedi INNO: self-locating, 6 retention forces, low profile. Sonator S straight (1–6 mm, up to 40°) and Sonator A angled. With caps, impression copings and analog.

DEFINITIVE PROSTHETICS · COWELLMEDI
INNO Sonator Abutment
Ball/snap attachment for implant-retained and implant-supported overdentures on Cowellmedi INNO implants. Self-locating, with six retention forces and suitable even with low vertical space – a cost-effective solution, also for retrofitting an existing denture.
INDICATION
Overdenture
maxilla and mandible
SEATING
Self-locating
denture finds its position
RETENTION
6 levels
approx. 10 to 22 N
DIVERGENCE
up to 40°
Sonator S, 2 implants
TORQUE
30 Ncm
with ratchet driver
SONATOR PRINCIPLE
Secure retention – even with limited space
The Sonator abutment is screwed into the implant, the housing with an exchangeable retention cap sits in the denture. Thanks to the self-locating design, the denture glides into the correct position by itself. Retention is adjusted with colour-coded caps that can be changed chairside at any time. The low profile makes Sonator suitable even where space is limited.
VARIANTS
Sonator S or Sonator A?
SONATOR S · STRAIGHT
Sonator S abutment

One-piece abutment screwed in directly with the ratchet driver – stable at low vertical height.

  • Gingival heights 1 to 6 mm
  • Divergence compensation up to 40° (2 implants)
  • H-type retention caps: white · pink · blue
  • Torque 30 Ncm
SONATOR A · ANGLED
Sonator A abutment

Two-piece abutment with abutment screw, for more inclined implants.

  • Gingival heights 1.5 and 3 mm
  • Divergence compensation up to 20° (2 implants)
  • NH-type retention caps: green · orange · red
  • screwed in with the 1.2 mm hex driver
RETENTION CAPS
Retention force by colour
Caps are inserted and changed with the I&R driver – so retention can be adjusted at any time.
Sonator S · H-type Retention Sonator A · NH-type Retention
white approx. 22 N green approx. 22 N
pink approx. 15 N orange approx. 15 N
blue approx. 10 N red approx. 10 N
Retention forces according to the manufacturer, approximate values. Start with medium retention and adjust as needed.
ORDER NUMBERS
Sonator abutments for INNO Ø 4.0
Gingival height = cuff height from the implant shoulder, choose according to the measured soft-tissue thickness.
Sonator S · straight
Gingival height Order no.
1.0 mm SONS401
2.0 mm SONS402
3.0 mm SONS403
4.0 mm SONS404
5.0 mm SONS405
6.0 mm SONS406
Sonator A · angled
Gingival height Order no.
1.5 mm SONA415
3.0 mm SONA430
ACCESSORIES
Caps, impression and instruments
Everything for impression, model and maintenance.
Accessory Use Order no.
Retention caps straight replacement caps for Sonator S SONIC01
Retention caps angled replacement caps for Sonator A SONIC02
Impression copings (4 pcs) abutment-level impression, open or closed SONIP04
Lab analogs (4 pcs) for the working cast SONLA04
Abutment screw for Sonator A 2SSHR300
Ratchet driver for screwing in Sonator S, with torque wrench SONRD19L
ALTERNATIVE
Prefer the Locator principle? – Dualock
If your practice works with Locator attachments, Dualock offers a cost-effective Locator-style alternative – for many implant systems, including Cowellmedi INNO.
View Dualock →
WORKFLOW
From impression to overdenture

1. Select the Sonator abutment according to gingival height and tighten to 30 Ncm.
2. Place impression copings and take an abutment-level impression.
3. Insert lab analogs into the impression and fabricate the working cast.
4. Process housings with retention caps into the denture – in the lab or chairside with block-out spacer.
5. Set retention by cap colour; change caps with the I&R driver as needed.

SUITABLE FOR
  • Overdentures in maxilla and mandible
  • Cases with low vertical space
  • Retrofitting an existing complete denture
  • Patients looking for a cost-effective implant solution
NOT SUITABLE FOR
  • Fixed restorations or cases requiring a rigid connection
  • Restoration on a single implant
  • Divergence above 40° with two implants
Note: All components except the ratchet and I&R drivers are single-use. Selection, tightening torque and processing follow Cowellmedi's current instructions for use.